Xtratherm Flat Roof Board FR-ALU
Xtratherm FR-ALU foil faced boards are suitable for use below PVC, TPO or EPDM single ply roof membranes and loose laid ballasted roofing.
Note: FR-ALU is not suitable for direct hot contact applications with built-up bitumen based roofing or mastic asphalt systems.
Xtratherm FR-ALU foil faced boards are suitable for use below PVC, TPO or EPDM single ply roof membranes and loose laid ballasted roofing.
Note: FR-ALU is not suitable for direct hot contact applications with built-up bitumen based roofing or mastic asphalt systems.
- High Thermal Performance
- Compatible with: - mechanically fixed single ply systems - loose laid ballasted systems
- Vapour resistant foil facers
TYPICAL PHYSICAL CHARACTERISTICS
| PROPERTY | UNITS |
|---|---|
| Density | 32 kg/m³ |
| Compressive Strength | >150 kPa @10% |
| Water Vapour Resistivity | >100MNs/gm |
| Thermal Conductivity | 0.022 W/mK |
| Service Temperature | -20°C +100°C |
SPANNING
| Xtratherm FR-ALU insulation boards laid over metal decks should be in accordance with BS 4841:Part 3 | ||
|---|---|---|
| mm | TROUGH OPENING (mm) | |
| 25 | 75 | |
| 30 | >75 | 100 |
| 35 | >100 | 125 |
| 40 | >125 | 150 |
| 45 | >150 | 175 |
| 50 | >175 | 200 |
TYPICAL 'U' VALUES
| FR-ALU Over Concrete Deck | |
|---|---|
| THICKNESS (mm) | U-Value (W/m²K) |
| 50 | 0.36 |
| 60 | 0.32 |
| 70 | 0.28 |
| 80 | 0.25 |
| 100 | 0.21 |
| 105 | 0.20 |
| 120 | 0.17 |
TOLERANCE
| DIMENSIONS | SIZE (mm) | TOLERANCE |
|---|---|---|
| Length | 2400 | +/- 5mm |
| Width | 1200 | +/- 3mm |
| Thickness | <60 | +/- 2mm |
| ≥60 | +/- 3mm | |
| Diagonals | Do not differ more than | 0.3% |
XTRATHERM FR-ALU SHEET SIZE
| DIMENSIONS | SIZE (mm) |
|---|---|
| Length | 2400 |
| Width | 1200 |
| Thickness | 25 | 50 | 60 | 70 | 75 | 80 | 100 | 110 | 120 |
Other sizes are available subject to quantity and lead time.
Roof Finishes: Consideration should be given to the recommendations of BS4841: Part 3 1987 and those of the Single Ply Roofing Association.
Falls: The fall on a flat roof should be constant and steep enough to ensure that rainfall does not pond. Care must be taken to provide adequate falls ie not less than 1-80 to rain water outlets.
Fire: The fire rating
when tested to BS 476 Part 3: 1968 "External Fire Exposure Roof Test" will
be dependent upon waterproofing system specified.
Xtratherm FR-ALU will typically achieve FAB rating.
See the Specification Clause
Xtratherm FR-ALU is faced with a gas-tight foil face.
Xtratherm FR-ALU foil faced roof boards are suitable for use below single ply mechanically fixed roof membranes.
Note: FR-ALU is not suitable for applications with built-up bitumen based roofing or mastic asphalt systems.
Xtratherm FR-ALU foil faced roof boards are suitable for use below single ply mechanically fixed roof membranes.
Note: FR-ALU is not suitable for applications with built-up bitumen based roofing or mastic asphalt systems.
Xtratherm FR-ALU foil faced insulation boards
are suitable for use on roof decks that are
subject to maintenance traffic. Walk ways
should be provided on roofs requiring regular
pedestrian access. When the roof is complete,
protective boarding should be laid if additional
site work is to be carried out. The completed
roof should not be used for storage of heavy
materials or air conditioning plant
Xtratherm FR-ALU insulation boards should be laid over the vapour
control layer in a break bonded pattern. The long edges of the boards
should be laid at right angles to the corrugations and all board joints
must be fully supported by the deck. The FR-ALU insulation boards are secured by approved mechanical fixings.
The requirement for a separate water vapour control layer should be assessed in accordance with BS6229 1982. When a vapour control layer is necessary, 1000 gauge polythene should be used. Any fixings that penetrate it must be of the self sealing type that fuse to the vapour control layer during applications.
The requirement for a separate water vapour control layer should be assessed in accordance with BS6229 1982. When a vapour control layer is necessary, 1000 gauge polythene should be used. Any fixings that penetrate it must be of the self sealing type that fuse to the vapour control layer during applications.
INSTALLATION GUIDELINES
Flat Roof Insulation
Vapour Control Layer
The water vapour control layer should be laid with 150mm laps, which are turned up at any vertical upstand. When the insulation boards have been positioned the laps are turned over and sealed, prior to the roof finish being completed.
Laying - Metal/Timber Deck
Xtratherm FR-ALU foil faced boards should be laid over the vapour control layer in a break bonded pattern. The long edges of the boards should be laid at right angles to the corrugations and all board joints must be fully supported by the deck. The FR-ALU insulation boards are generally secured by approved mechanical fixings.
Laying - Concrete Deck
Xtratherm FR-ALU boards are laid over the vapour control layer in a break bonded pattern and secured with approved mechanical fixings, or secured under ballasted system. Care should be taken to ensure that the concrete deck is graded to the correct falls, is dry, clean and free from any projections or gaps.
Fixing
The specification for fixing of Xtratherm roof boards will vary with the location, roof height/width and topographical data, architectural specification should be consulted.
Generally with 1200 x 600 boards, a minimum of 4 fixings are adequate, located between 50mm and 150mm from all edges, additional fixings may be placed along the centre line. 11 fixings per 2.4 x 1.2m sheet is recommended. Counter sunk washers, 50mm in diameter should be used with each fixing. However, BS6399 Part 2 1995 should always be consulted. During the construction process, the construction should be protected from rain penetration during breaks in the process.
Vapour Control Layer
The water vapour control layer should be laid with 150mm laps, which are turned up at any vertical upstand. When the insulation boards have been positioned the laps are turned over and sealed, prior to the roof finish being completed.
Laying - Metal/Timber Deck
Xtratherm FR-ALU foil faced boards should be laid over the vapour control layer in a break bonded pattern. The long edges of the boards should be laid at right angles to the corrugations and all board joints must be fully supported by the deck. The FR-ALU insulation boards are generally secured by approved mechanical fixings.
Laying - Concrete Deck
Xtratherm FR-ALU boards are laid over the vapour control layer in a break bonded pattern and secured with approved mechanical fixings, or secured under ballasted system. Care should be taken to ensure that the concrete deck is graded to the correct falls, is dry, clean and free from any projections or gaps.
Fixing
The specification for fixing of Xtratherm roof boards will vary with the location, roof height/width and topographical data, architectural specification should be consulted.
Generally with 1200 x 600 boards, a minimum of 4 fixings are adequate, located between 50mm and 150mm from all edges, additional fixings may be placed along the centre line. 11 fixings per 2.4 x 1.2m sheet is recommended. Counter sunk washers, 50mm in diameter should be used with each fixing. However, BS6399 Part 2 1995 should always be consulted. During the construction process, the construction should be protected from rain penetration during breaks in the process.